| wdt_ID | URD ID | User Requirement | Type of URD (Safety/Performance) | Safety Thresholds / Targets | Rationale for Requirement |
|---|---|---|---|---|---|
| 366 | |||||
| 367 | 1 | User shall be compliant with Legislation, including HSE Legislation | Safety | Meet the legislation | legislative compliant system and avoid unacceptable risk to personnel working around the system. |
| 368 | 2 | Isolate the Well Head from Oil Transfer System within 10 seconds | Performance | Isolate Well Head from Oil SSTS within 10 seconds | Maximise safety. minimise platform down time |
| 369 | 3 | Ability to receive crude oil from the extraction point off the rig, at pressures up to 20 bar | Performance | Pressure up to 20 bar | Maximise safety, minimise platform down time |
| 370 | 4 | Comply with Regulations | Safety | Compliance with Regulations such as; (i) noise at work regulations, (ii) control of pollutions | Ensure adherence to Health & Safety practices and legal compliance |
| 371 | 5 | Capability shall provide for extraction of crude oil from provided hydrocarbons (from well head) | Performance | Seperation of Crude Oil into; (i) gas, (ii) water, (iii) sediment, (iv) processed oil | Fulfilment of design intent |
| 372 | 6 | Capability shall provide for storage of crude oil | Performance | tbc | Fulfilment of design intent |
| 373 | 7 | Capability shall provide for transfer of crude oil to tanker | Performance | tbc | Fulfilment of design intent |
| 374 | 8 | Capability shall provide for measurement of offloaded oil (to tanker) | Performance | tbc | Fulfilment of design intent |
| 375 | 9 | Capability shall provide for continuous operations | Performance | Duty/standby? Something for reliability / integrity levels | Fulfilment of design intent |
| wdt_ID | URD (Safety Requirement) | SRD ID | SRD (Safety Requirement) |
|---|---|---|---|
| 444 | User shall be compliant with Legislation, including HSE Legislation | 1 | The SSTS shall comply with all relevant current and known impending EU and UK Health and Safety legislation. |
| 445 | Isolate the Well Head from Oil Transfer System within 10 seconds | 2 | The SSTS shall be able to isolate from the Well Head, to cease movement of oil, within 10 seconds of activation of an Emergency Stop signal being sent from any point for oil flow chain |
| 447 | The system shall be able to be isolated from the tanker within 10 seconds | 3 | The SSTS shall be able to isolate from the tanker, to cease movement of oil, within 10 seconds of activation of an Emergency Stop signal being sent from any point for oil flow chain |
| 448 | The system shall includes means to prevent overpressure | 4 | The SSTS shall be able to safely manage overpressure of greater than 20 Bar |
| 449 | The Target Safety Objective for the project shall be <1E-6 catastrophic repercussions per year | 5 | The Systems safety target for an catastrophic repercussions per year is <1E-6. The SSTS shall met the Safety target. The System shall provide the evidence and the documentation to show that the safety targets have been achieved. |
| 450 | All risks shall be reduced to at least Tolerable Levels that are ALARP | 6 | The SSTS must be designed wherever possible so that all risks are no higher than Tolerable and ALARP. If risks cannot be minimised to Tolerable and ALARP through design, other mitigations should be used. |
| 451 | The system shall be safe to operate at all expected pressures (20bar-8 bar) | 7 | The SSTS shall be a capable of operating with the design pressure design envelope of greater than 8 bar and less than 20 bar and have means to isolate and shut itself down when pressures are outwith the design range. |
| SRD Requirement | wdt_ID | Option A (5 Fully Compliant - 0 = Non Compliant) | Option B (5 Fully Compliant - 0 = Non Compliant) | Option C (5 Fully Compliant - 0 = Non Compliant) |
|---|---|---|---|---|
| The SSTS must be designed wherever possible so that all risks are no higher than Tolerable and ALARP. If risks cannot be minimised to Tolerable and ALARP through design, other mitigations should be used. | 374 | 3 | 3 | 3 |
| The SSTS shall be a capable of operating with the design pressure design envelope of greater than 8 bar and less than 20 bar and have means to isolate and shut itself down when pressures are outwith the design range. | 375 | 5 | 5 | 5 |
| The SSTS shall be able to isolate from the tanker, to cease movement of oil, within 10 seconds of activation of an Emergency Stop signal being sent from any point for oil flow chain | 376 | 5 | 1 | 2 |
| The SSTS shall be able to isolate from the Well Head, to cease movement of oil, within 10 seconds of activation of an Emergency Stop signal being sent from any point for oil flow chain | 377 | 5 | 1 | 2 |
| The SSTS shall be able to safely manage overpressure of greater than 20 Bar | 378 | 5 | 5 | 5 |
| The SSTS shall comply with all relevant current and known impending EU and UK Health and Safety legislation. | 379 | 2 | 1 | 3 |
| The Systems safety target for an catastrophic repercussions per year is <1E-6. The SSTS shall met the Safety target. The System shall provide the evidence and the documentation to show that the safety targets have been achieved. | 380 | 0 | 0 | 0 |